{"id":9720,"date":"2026-11-03T14:40:42","date_gmt":"2026-11-03T13:40:42","guid":{"rendered":"https:\/\/bf-engineering.dev10.econsor-programming.de\/?post_type=anwendung&#038;p=9720"},"modified":"2026-11-04T08:19:14","modified_gmt":"2026-11-04T07:19:14","slug":"sistemas-de-climatizacion","status":"publish","type":"anwendung","link":"https:\/\/bf-engineering.dev10.econsor-programming.de\/es\/aplicacion\/sistemas-de-climatizacion\/","title":{"rendered":"Sistemas de climatizaci\u00f3n"},"content":{"rendered":"","protected":false},"excerpt":{"rendered":"","protected":false},"author":7,"featured_media":10220,"menu_order":8,"template":"","meta":{"_acf_changed":false,"footnotes":""},"anwendung-kat":[122],"produkt-kat":[],"class_list":["post-9720","anwendung","type-anwendung","status-publish","has-post-thumbnail","hentry","anwendung-kat-ferrocarril","no-featured-image-padding"],"acf":{"cpt-modules":{"":null,"description":"<strong>Simulaci\u00f3n solar para ensayos de sistemas de climatizaci\u00f3n<\/strong>\r\n\r\nEl sistema de climatizaci\u00f3n de un veh\u00edculo ferroviario debe responder a condiciones externas cambiantes y a diferentes cargas t\u00e9rmicas internas. La radiaci\u00f3n solar aumenta el aporte de calor a trav\u00e9s de la carrocer\u00eda y los acristalamientos, influyendo as\u00ed en la capacidad frigor\u00edfica necesaria. Al mismo tiempo, deben alcanzarse unas condiciones t\u00e9rmicas lo m\u00e1s estables posible en las zonas ocupadas relevantes.\r\n\r\nUna simulaci\u00f3n solar adaptada a la aplicaci\u00f3n proporciona cargas externas definidas para estas investigaciones. En combinaci\u00f3n con el resto del entorno de ensayo, permite analizar el comportamiento de enfriamiento de un veh\u00edculo previamente calentado, el mantenimiento de la temperatura durante el funcionamiento y la respuesta a cambios de carga.\r\n\r\nBF Engineering desarrolla tecnolog\u00eda de irradiaci\u00f3n para estas tareas de ensayo. El dise\u00f1o se adapta al veh\u00edculo, a la secuencia de ensayo y a las interfaces con el entorno de ensayos clim\u00e1ticos existente.","button":null,"text":{"title":"","description":"","button":null},"gallery":"","references":"","tabs":[{"title":"Capacidad frigor\u00edfica","description":"<strong>Evaluar la climatizaci\u00f3n bajo una carga solar sostenida<\/strong>\r\n\r\nBajo irradiaci\u00f3n solar, el veh\u00edculo absorbe calor de forma continua. El sistema de climatizaci\u00f3n debe compensar este aporte de calor junto con otras cargas externas e internas. Por ello, resulta relevante investigar c\u00f3mo evolucionan las condiciones interiores bajo una carga definida.\r\n\r\nUna secuencia de ensayo habitual comienza con una fase de calentamiento establecida. A continuaci\u00f3n, se analiza la rapidez con la que la climatizaci\u00f3n alcanza las condiciones objetivo definidas. El funcionamiento bajo irradiaci\u00f3n sostenida tambi\u00e9n puede mostrar si estas condiciones se mantienen durante el periodo de ensayo previsto.\r\n\r\nLa evaluaci\u00f3n del comportamiento del veh\u00edculo y la determinaci\u00f3n de la capacidad frigor\u00edfica mediante mediciones son tareas diferentes. Mientras que el comportamiento de enfriamiento puede describirse mediante mediciones en el interior, determinar la capacidad frigor\u00edfica real requiere un montaje de medici\u00f3n adecuado.\r\n\r\n\u00c1mbitos habituales de investigaci\u00f3n:\r\n<ul>\r\n \t<li>Evoluci\u00f3n del enfriamiento tras una fase de calentamiento definida<\/li>\r\n \t<li>Tiempo necesario para alcanzar las condiciones interiores establecidas<\/li>\r\n \t<li>Distribuci\u00f3n de la temperatura durante el funcionamiento en refrigeraci\u00f3n<\/li>\r\n \t<li>Estabilidad de las condiciones bajo irradiaci\u00f3n sostenida<\/li>\r\n \t<li>Comportamiento con diferentes cargas t\u00e9rmicas externas e internas<\/li>\r\n<\/ul>","button":null,"image":"","tables":null},{"title":"Regulaci\u00f3n","description":"<strong>Investigar de forma claramente definida las respuestas a cambios de carga<\/strong>\r\n\r\nDurante el funcionamiento, las exigencias de climatizaci\u00f3n cambian continuamente. Una modificaci\u00f3n de la carga solar, cargas t\u00e9rmicas internas adicionales o un cambio del estado de funcionamiento pueden requerir ajustes en la capacidad frigor\u00edfica, el caudal de aire y su distribuci\u00f3n.\r\n\r\nLos perfiles de ensayo definidos permiten investigar c\u00f3mo responde la regulaci\u00f3n a estos cambios. Pueden analizarse, por ejemplo, el tiempo de respuesta, las desviaciones temporales de temperatura y la posterior estabilizaci\u00f3n. Tambi\u00e9n pueden ser relevantes las diferencias entre las distintas zonas del veh\u00edculo.\r\n\r\nPara comparar diferentes versiones de software o par\u00e1metros de regulaci\u00f3n, los perfiles de carga y las condiciones iniciales deben ser suficientemente equivalentes. Los cambios temporales que deba reproducir el sistema de irradiaci\u00f3n se establecen durante su dise\u00f1o.\r\n\r\nPosibles \u00e1mbitos de investigaci\u00f3n:\r\n<ul>\r\n \t<li>Respuesta a cambios en la carga solar<\/li>\r\n \t<li>Tiempo necesario para estabilizarse despu\u00e9s de un cambio de carga<\/li>\r\n \t<li>Desviaciones temporales respecto a las condiciones objetivo establecidas<\/li>\r\n \t<li>Transiciones entre diferentes estados de funcionamiento<\/li>\r\n \t<li>Comparaci\u00f3n de distintos par\u00e1metros de regulaci\u00f3n y versiones de software<\/li>\r\n<\/ul>","button":null,"image":"","tables":null},{"title":"Demanda energ\u00e9tica","description":"<strong>Considerar conjuntamente las condiciones interiores alcanzadas y la energ\u00eda utilizada<\/strong>\r\n\r\nUna estrategia de climatizaci\u00f3n no se eval\u00faa \u00fanicamente por las temperaturas que alcanza. Tambi\u00e9n son relevantes la energ\u00eda el\u00e9ctrica necesaria y las condiciones de carga bajo las que funciona el sistema.\r\n\r\nLas secuencias de ensayo definidas permiten comparar diferentes estrategias de funcionamiento en condiciones comparables. Para ello, la potencia el\u00e9ctrica consumida y las condiciones interiores se registran durante el mismo periodo. Adem\u00e1s de los picos individuales de potencia, resulta especialmente significativo el consumo energ\u00e9tico a lo largo de toda la secuencia de ensayo.\r\n\r\nPara realizar una comparaci\u00f3n fundamentada, debe definirse claramente el alcance del sistema evaluado. Seg\u00fan la tarea de medici\u00f3n, pueden incluirse, por ejemplo, compresores, ventiladores, bombas y otros consumidores auxiliares. Al evaluar los resultados, deben tenerse en cuenta las diferencias en las temperaturas interiores o en los perfiles de carga.\r\n\r\nPar\u00e1metros relevantes de evaluaci\u00f3n:\r\n<ul>\r\n \t<li>Potencia el\u00e9ctrica consumida por los componentes evaluados<\/li>\r\n \t<li>Consumo energ\u00e9tico durante el periodo de ensayo definido<\/li>\r\n \t<li>Condiciones de temperatura y, cuando corresponda, de confort t\u00e9rmico alcanzadas<\/li>\r\n \t<li>Perfil de carga y duraci\u00f3n de cada fase de funcionamiento<\/li>\r\n \t<li>Comparaci\u00f3n de estrategias de funcionamiento con condiciones de contorno equivalentes<\/li>\r\n<\/ul>","button":null,"image":"","tables":null},{"title":"Condiciones de ensayo","description":"<strong>Definir claramente las cargas externas y los estados del veh\u00edculo<\/strong>\r\n\r\nLa validez de un ensayo de climatizaci\u00f3n depende en gran medida de las condiciones de contorno establecidas. La temperatura ambiente, la humedad, la irradiaci\u00f3n y el estado inicial del veh\u00edculo influyen tanto en el comportamiento de enfriamiento como en la demanda energ\u00e9tica.\r\n\r\nSeg\u00fan el objetivo del ensayo, pueden incorporarse otras influencias. Entre ellas se encuentran el flujo de aire alrededor del veh\u00edculo, las cargas t\u00e9rmicas internas adicionales o las secuencias de apertura de puertas establecidas. Estas condiciones deben ajustarse al objetivo de la investigaci\u00f3n y describirse de forma clara en la secuencia de ensayo.\r\n\r\nEn los ensayos de unidades de climatizaci\u00f3n individuales, la carga t\u00e9rmica se aplica mediante un banco de ensayo adecuado. La irradiaci\u00f3n de un veh\u00edculo completo y la reproducci\u00f3n de la carga en una unidad de climatizaci\u00f3n individual cumplen funciones diferentes. Si se desea establecer una relaci\u00f3n entre ambos ensayos, deben coordinarse las hip\u00f3tesis de carga y los l\u00edmites del sistema.\r\n\r\nCondiciones de contorno importantes:\r\n<ul>\r\n \t<li>Temperatura ambiente y humedad<\/li>\r\n \t<li>Carga solar, distribuci\u00f3n espacial y evoluci\u00f3n temporal<\/li>\r\n \t<li>Temperaturas iniciales y acondicionamiento previo del veh\u00edculo<\/li>\r\n \t<li>Cargas t\u00e9rmicas internas y configuraci\u00f3n definida del veh\u00edculo<\/li>\r\n \t<li>Estados de funcionamiento, valores de consigna y, cuando corresponda, cambios de carga adicionales<\/li>\r\n<\/ul>","button":null,"image":"","tables":null},{"title":"Integraci\u00f3n","description":"<strong>Coordinar la irradiaci\u00f3n, el entorno de ensayo clim\u00e1tico y la adquisici\u00f3n de datos<\/strong>\r\n\r\nPara que la simulaci\u00f3n solar contribuya adecuadamente a la secuencia de ensayo, la tecnolog\u00eda de irradiaci\u00f3n, la c\u00e1mara clim\u00e1tica y los equipos de medici\u00f3n se consideran conjuntamente. Las fases de funcionamiento previstas determinan cu\u00e1ndo debe estar disponible la irradiaci\u00f3n y c\u00f3mo deben registrarse sus estados en el registro del ensayo.\r\n\r\nAdem\u00e1s de la alimentaci\u00f3n el\u00e9ctrica, debe tenerse en cuenta el calor adicional emitido por el sistema. Este influye en los requisitos del entorno de ensayo y debe contemplarse en su dise\u00f1o. La posici\u00f3n de las luminarias tambi\u00e9n debe coordinarse con el flujo de aire alrededor del veh\u00edculo, los puntos de medici\u00f3n y los accesos necesarios.\r\n\r\nBF Engineering se encarga del dise\u00f1o de la tecnolog\u00eda de irradiaci\u00f3n y coordina las interfaces correspondientes con los socios participantes en la instalaci\u00f3n. Seg\u00fan el proyecto, estas incluyen se\u00f1ales de control, mensajes de estado, se\u00f1ales de habilitaci\u00f3n y la correlaci\u00f3n temporal entre los estados de irradiaci\u00f3n y los datos de medici\u00f3n registrados.\r\n\r\nAspectos relevantes para la integraci\u00f3n:\r\n<ul>\r\n \t<li>Superficie de irradiaci\u00f3n, disposici\u00f3n de las luminarias y distancia al veh\u00edculo<\/li>\r\n \t<li>Alimentaci\u00f3n el\u00e9ctrica y calor adicional emitido<\/li>\r\n \t<li>Coordinaci\u00f3n con el flujo de aire, los sensores y las zonas de mantenimiento<\/li>\r\n \t<li>Interfaces de control, se\u00f1ales de habilitaci\u00f3n y mensajes de estado<\/li>\r\n \t<li>Correlaci\u00f3n temporal entre los estados de carga y los datos de medici\u00f3n<\/li>\r\n<\/ul>","button":null,"image":"","tables":null}]},"contact-person_selection":""},"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.8 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Sistemas de climatizaci\u00f3n | BF Engineering<\/title>\n<meta name=\"robots\" content=\"noindex, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/bf-engineering.dev10.econsor-programming.de\\\/es\\\/aplicacion\\\/sistemas-de-climatizacion\\\/\",\"url\":\"https:\\\/\\\/bf-engineering.dev10.econsor-programming.de\\\/es\\\/aplicacion\\\/sistemas-de-climatizacion\\\/\",\"name\":\"Sistemas de climatizaci\u00f3n | BF Engineering\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/bf-engineering.dev10.econsor-programming.de\\\/es\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/bf-engineering.dev10.econsor-programming.de\\\/es\\\/aplicacion\\\/sistemas-de-climatizacion\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/bf-engineering.dev10.econsor-programming.de\\\/es\\\/aplicacion\\\/sistemas-de-climatizacion\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/bf-engineering.dev10.econsor-programming.de\\\/wp-content\\\/uploads\\\/sites\\\/2\\\/2026\\\/11\\\/Solarsimulation.png\",\"datePublished\":\"2026-11-03T13:40:42+00:00\",\"dateModified\":\"2026-11-04T07:19:14+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/bf-engineering.dev10.econsor-programming.de\\\/es\\\/aplicacion\\\/sistemas-de-climatizacion\\\/#breadcrumb\"},\"inLanguage\":\"es\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/bf-engineering.dev10.econsor-programming.de\\\/es\\\/aplicacion\\\/sistemas-de-climatizacion\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"es\",\"@id\":\"https:\\\/\\\/bf-engineering.dev10.econsor-programming.de\\\/es\\\/aplicacion\\\/sistemas-de-climatizacion\\\/#primaryimage\",\"url\":\"https:\\\/\\\/bf-engineering.dev10.econsor-programming.de\\\/wp-content\\\/uploads\\\/sites\\\/2\\\/2026\\\/11\\\/Solarsimulation.png\",\"contentUrl\":\"https:\\\/\\\/bf-engineering.dev10.econsor-programming.de\\\/wp-content\\\/uploads\\\/sites\\\/2\\\/2026\\\/11\\\/Solarsimulation.png\",\"width\":1280,\"height\":1280,\"caption\":\"Solarsimulation\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/bf-engineering.dev10.econsor-programming.de\\\/es\\\/aplicacion\\\/sistemas-de-climatizacion\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/bf-engineering.dev10.econsor-programming.de\\\/es\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Aplicaciones\",\"item\":\"https:\\\/\\\/bf-engineering.dev10.econsor-programming.de\\\/es\\\/aplicacion\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Ferrocarril\",\"item\":\"https:\\\/\\\/bf-engineering.dev10.econsor-programming.de\\\/es\\\/aplicacion\\\/categoria\\\/ferrocarril\\\/\"},{\"@type\":\"ListItem\",\"position\":4,\"name\":\"Sistemas de climatizaci\u00f3n\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/bf-engineering.dev10.econsor-programming.de\\\/es\\\/#website\",\"url\":\"https:\\\/\\\/bf-engineering.dev10.econsor-programming.de\\\/es\\\/\",\"name\":\"BF Engineering\",\"description\":\"Engineering the Sun\",\"publisher\":{\"@id\":\"https:\\\/\\\/bf-engineering.dev10.econsor-programming.de\\\/es\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/bf-engineering.dev10.econsor-programming.de\\\/es\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"es\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/bf-engineering.dev10.econsor-programming.de\\\/es\\\/#organization\",\"name\":\"BF Engineering\",\"url\":\"https:\\\/\\\/bf-engineering.dev10.econsor-programming.de\\\/es\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"es\",\"@id\":\"https:\\\/\\\/bf-engineering.dev10.econsor-programming.de\\\/es\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/bf-engineering.dev10.econsor-programming.de\\\/wp-content\\\/uploads\\\/sites\\\/2\\\/2026\\\/06\\\/logo_bf-engineering.svg\",\"contentUrl\":\"https:\\\/\\\/bf-engineering.dev10.econsor-programming.de\\\/wp-content\\\/uploads\\\/sites\\\/2\\\/2026\\\/06\\\/logo_bf-engineering.svg\",\"caption\":\"BF Engineering\"},\"image\":{\"@id\":\"https:\\\/\\\/bf-engineering.dev10.econsor-programming.de\\\/es\\\/#\\\/schema\\\/logo\\\/image\\\/\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Sistemas de climatizaci\u00f3n | BF Engineering","robots":{"index":"noindex","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/bf-engineering.dev10.econsor-programming.de\/es\/aplicacion\/sistemas-de-climatizacion\/","url":"https:\/\/bf-engineering.dev10.econsor-programming.de\/es\/aplicacion\/sistemas-de-climatizacion\/","name":"Sistemas de climatizaci\u00f3n | BF Engineering","isPartOf":{"@id":"https:\/\/bf-engineering.dev10.econsor-programming.de\/es\/#website"},"primaryImageOfPage":{"@id":"https:\/\/bf-engineering.dev10.econsor-programming.de\/es\/aplicacion\/sistemas-de-climatizacion\/#primaryimage"},"image":{"@id":"https:\/\/bf-engineering.dev10.econsor-programming.de\/es\/aplicacion\/sistemas-de-climatizacion\/#primaryimage"},"thumbnailUrl":"https:\/\/bf-engineering.dev10.econsor-programming.de\/wp-content\/uploads\/sites\/2\/2026\/11\/Solarsimulation.png","datePublished":"2026-11-03T13:40:42+00:00","dateModified":"2026-11-04T07:19:14+00:00","breadcrumb":{"@id":"https:\/\/bf-engineering.dev10.econsor-programming.de\/es\/aplicacion\/sistemas-de-climatizacion\/#breadcrumb"},"inLanguage":"es","potentialAction":[{"@type":"ReadAction","target":["https:\/\/bf-engineering.dev10.econsor-programming.de\/es\/aplicacion\/sistemas-de-climatizacion\/"]}]},{"@type":"ImageObject","inLanguage":"es","@id":"https:\/\/bf-engineering.dev10.econsor-programming.de\/es\/aplicacion\/sistemas-de-climatizacion\/#primaryimage","url":"https:\/\/bf-engineering.dev10.econsor-programming.de\/wp-content\/uploads\/sites\/2\/2026\/11\/Solarsimulation.png","contentUrl":"https:\/\/bf-engineering.dev10.econsor-programming.de\/wp-content\/uploads\/sites\/2\/2026\/11\/Solarsimulation.png","width":1280,"height":1280,"caption":"Solarsimulation"},{"@type":"BreadcrumbList","@id":"https:\/\/bf-engineering.dev10.econsor-programming.de\/es\/aplicacion\/sistemas-de-climatizacion\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/bf-engineering.dev10.econsor-programming.de\/es\/"},{"@type":"ListItem","position":2,"name":"Aplicaciones","item":"https:\/\/bf-engineering.dev10.econsor-programming.de\/es\/aplicacion\/"},{"@type":"ListItem","position":3,"name":"Ferrocarril","item":"https:\/\/bf-engineering.dev10.econsor-programming.de\/es\/aplicacion\/categoria\/ferrocarril\/"},{"@type":"ListItem","position":4,"name":"Sistemas de climatizaci\u00f3n"}]},{"@type":"WebSite","@id":"https:\/\/bf-engineering.dev10.econsor-programming.de\/es\/#website","url":"https:\/\/bf-engineering.dev10.econsor-programming.de\/es\/","name":"BF Engineering","description":"Engineering the Sun","publisher":{"@id":"https:\/\/bf-engineering.dev10.econsor-programming.de\/es\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/bf-engineering.dev10.econsor-programming.de\/es\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"es"},{"@type":"Organization","@id":"https:\/\/bf-engineering.dev10.econsor-programming.de\/es\/#organization","name":"BF Engineering","url":"https:\/\/bf-engineering.dev10.econsor-programming.de\/es\/","logo":{"@type":"ImageObject","inLanguage":"es","@id":"https:\/\/bf-engineering.dev10.econsor-programming.de\/es\/#\/schema\/logo\/image\/","url":"https:\/\/bf-engineering.dev10.econsor-programming.de\/wp-content\/uploads\/sites\/2\/2026\/06\/logo_bf-engineering.svg","contentUrl":"https:\/\/bf-engineering.dev10.econsor-programming.de\/wp-content\/uploads\/sites\/2\/2026\/06\/logo_bf-engineering.svg","caption":"BF Engineering"},"image":{"@id":"https:\/\/bf-engineering.dev10.econsor-programming.de\/es\/#\/schema\/logo\/image\/"}}]}},"_links":{"self":[{"href":"https:\/\/bf-engineering.dev10.econsor-programming.de\/es\/wp-json\/wp\/v2\/anwendung\/9720","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/bf-engineering.dev10.econsor-programming.de\/es\/wp-json\/wp\/v2\/anwendung"}],"about":[{"href":"https:\/\/bf-engineering.dev10.econsor-programming.de\/es\/wp-json\/wp\/v2\/types\/anwendung"}],"author":[{"embeddable":true,"href":"https:\/\/bf-engineering.dev10.econsor-programming.de\/es\/wp-json\/wp\/v2\/users\/7"}],"version-history":[{"count":3,"href":"https:\/\/bf-engineering.dev10.econsor-programming.de\/es\/wp-json\/wp\/v2\/anwendung\/9720\/revisions"}],"predecessor-version":[{"id":9732,"href":"https:\/\/bf-engineering.dev10.econsor-programming.de\/es\/wp-json\/wp\/v2\/anwendung\/9720\/revisions\/9732"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/bf-engineering.dev10.econsor-programming.de\/es\/wp-json\/wp\/v2\/media\/10220"}],"wp:attachment":[{"href":"https:\/\/bf-engineering.dev10.econsor-programming.de\/es\/wp-json\/wp\/v2\/media?parent=9720"}],"wp:term":[{"taxonomy":"anwendung-kat","embeddable":true,"href":"https:\/\/bf-engineering.dev10.econsor-programming.de\/es\/wp-json\/wp\/v2\/anwendung-kat?post=9720"},{"taxonomy":"produkt-kat","embeddable":true,"href":"https:\/\/bf-engineering.dev10.econsor-programming.de\/es\/wp-json\/wp\/v2\/produkt-kat?post=9720"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}